Pump producer KSB writes about its involvement in a current venture to improve a 50-year-old potable water pumping station in Canada. The station provides round 420k individuals and supplies as much as 340m L/day

The RDLO pumps are rated for 1,300 L/s or 900 L/sec and every of the pumps’ discharge piping is supplied with a 600mm diameter tilting disk test & throttling valve and isolation ball valve every with a motorized actuator.

For half a century residents and commerce throughout eight municipalities of the better London Space of south western Ontario have obtained their potable water provide from Lake Huron Water Remedy Plant (WTP) close to Grand Bend and over this era the neighborhood has been effectively served. Nevertheless, in 2017 the Lake Huron Main Water Provide System (LHPWSS) introduced an Power Audit and Pump Optimization research that recognized a big alternative for power financial savings and the optimization of pump operations for the pumping station.

The result of this research has been the modification of the unique 5 pump configuration within the pump station and its substitute with a six pump configuration. This has concerned eradicating three of the unique 50-year outdated 3000hp (2237kW) pumps and changing them with 4 excessive raise pumps from KSB. With the brand new pumps operating on their operational curve, substantial power financial savings might be made. As {an electrical} transmission-connected entity, the LHPWSS was eligible beneath the Impartial Electrical energy Methods Operator’s (IESO) Industrial Accelerator Program (IEP) for monetary incentives for eligible power effectivity tasks.

4 worldwide pump producers submitted bids, however KSB Canada’s submission stood out. Regardless of being the best capital expenditure price by a big quantity, KSB’s submission really provided the bottom general anticipated lifecycle price over 25 years. This was doable because of KSB’s spectacular power effectivity and inventive resolution in providing a single kind for all 4 pumps (giant and small.) This diminished the spares requirement, in flip lowering the lifecycle price and offering flexibility to simply enhance pump capability sooner or later as demand continues to extend. The contract was awarded to KSB Canada, who commenced design and session work in 2019. Pump manufacturing started in 2020 and the up to date pumping station grew to become totally operational August 2022.

Lake Huron: Main provide

Situated in Southwestern Ontario, alongside the Quebec Metropolis-Winsor Hall, London is an fascinating Metropolis because it will get its water supply from each Lake Huron and Lake Erie. The Regional Water Provide Division of the Metropolis of London (RWS) is seconded to the regional Water Boards and chargeable for two main water provide methods, these being the LHPWSS and the Elgin Space Main Water Provide System (EAPWSS). The LHPWSS companies the municipalities of London, Lambton Shores, North Middlesex, South Huron, Bluewater, Middlesex Centre, Lucan-Biddulph and Strathroy-Caradoc from a water therapy plant situated north of the village of Grand Bend in South Huron. The plant has a present therapy capability of 340 million liters per day (75 million imperial gallons per day) and serves town’s inhabitants of roughly 420,000 individuals within the eight municipalities, together with 80% of the Metropolis of London.

The pumping station was initially designed for a single pipeline, however later in 1996 and 2014 the RWS partially twinned the 47km important transmission pipeline to a terminal reservoir ensuing within the pumps now not operating on their curve. “After nearly 50 years, the present pumps have been changing into inefficient, with the impellers exhibiting indicators of pitting. Retaining them operational required loads of ongoing upkeep as a result of they have been operating off curve,” stories Billy Haklander, Capital Program Supervisor, LH&EAPWSS.

Pump choice

The overriding points which the pumps suppliers confronted have been delivering power financial savings and guaranteeing that pumps could possibly be accommodated within the restricted house within the pump corridor and that the ground might stand up to their weight. As well as the provider wanted to ensure a large working vary with low out there NPSH, masking a number of responsibility situations with pumps working at full velocity.

To provide the LHPWSS essentially the most flexibility in deciding on pumps, 4 pump suppliers have been invited to submit separate bids for the small and huge pumps and to establish a credit score ought to the LH&EAPWSS resolve to supply each the small and huge pumps from the identical provider. KSB’s bid provided a artistic resolution utilizing only a single kind for all 4 pumps, with solely the impellers and motors being totally different in accordance with the scale of the pump.

The bottom plates for every pump have been the identical measurement. The pliability provided by KSB enabled the capital price of its bid to be adjusted to account for fewer spares and thereby create financial savings for the shopper.

A big advantage of the proposal made by KSB was that with the smaller pumps utilizing the identical measurement casings and base plates as the 2 bigger pumps, that they had engineered the chance to extend the pump measurement by becoming bigger impellers and motors at a future date. This may be finished on website with none civil works needing to be carried out. Thus, if demand grows for the water provide to be elevated it may be accommodated with the minimal of price and disruption to the plant.

Following a 25 yr Life Cycle Price evaluation, making an allowance for the capital price, power consumption and upkeep prices made by AECOM Canada, consultants for LH&EAPWSS, the contract was awarded to KSB. Provided that the pumps proposed by KSB met the technical necessities and provided the bottom general anticipated lifecycle price over 25 years, AECOM and RWS really useful that the proposal from KSB be accepted.

Set up challenges

“One of many constraints that we needed to think about when evaluating the bidders’ venture was skill to evolve to the out there house within the current pump corridor “explains Marcus Henderson, KSB Nationwide Operations Supervisor. “With this being an current set up there was solely a lot actual property to work with and a key constraint was that the present pumps have been of a backside suction configuration. Often, the set up configuration for horizontal cut up case pumps is in-line with the suction and discharge in the identical path. This meant that we needed to discover a resolution to include backside suction. We needed to undertake some sample work to include the present pipework which enabled us to unravel the issue.”

“The eventual scope of the venture concerned the availability of 4 backside suction horizontal cut up case pumps, vibration monitoring system and move straighteners (suction conditioning spools) for potable water distribution (water provide)”, stories Marcus Henderson. “Additionally, a part of the contract was to provide two TECO make 1494kW/2000hp @ 1200rpm, 4160V / 3Ph/60Hz and two TECO make 2611Kw/3500hp @ 1200rpm, 4160V / 3Ph/60Hz electrical motors. We have been additionally chargeable for torsional and lateral evaluation for the pump units, on website start-up and commissioning area companies.”

The plant’s pumps are rated for 1,158 L/s, and every of the pumps’ discharge piping is supplied with a 500mm diameter tilting disk test valve, together with a 500mm diameter steel seated ball valve outfitted with a motorized electrical actuator. The WTP has two hydro pneumatic tanks, every with a capability of 580m³, for transient safety of the 47km partially twinned 1200mm diameter water important distribution system.

RDLO pumps

Confirmed in lots of water purposes around the globe, the RDLO pumps have been recognized as being greater than able to assembly the shopper’s particular calls for. KSB’s RDLO axially cut up, single stage volute pumps have been developed particularly for dealing with uncooked water, clear water, service water and transport fluids with a minimal of move resistance. In consequence, they decrease the power and life cycle prices of the methods by which they’re put in. In addition they provide reliability and excessive availability: Reliability from the casing halves being sealed by strong casing cut up flanges on the higher and decrease casing half, and excessive availability from using generously-dimensioned bearings and high-quality shaft seals.
The mix of strong bearing brackets, a brief and inflexible shaft and pre-loaded bearings ensures low vibration and prolonged working life for the bearings, seals and coupling.

Being axially cut up case pumps simplifies upkeep procedures, enabling prepared entry to all components for thorough inspection. The drive could also be positioned on each the left and proper of the pump with out further components or modifications to the casing being essential. ”Two of the pumps are related as much as 3500 hp motors and the opposite two to 2500 hp motors.

These are the principle pumps supplying consuming water to all the LHPWSS with many shoppers over 50km away, so that they devour a large amount of power. It’s marginal enhancements comparable to these that may enhance effectivity by one or two p.c, however they work out to large {dollars} when you think about the general measurement of the plant,” says Marcus Henderson.

Set up

“As a result of the pumps have been being retrofitted into the unique premises, it was essential to run the plant at half capability on one transmission aspect throughout set up,” explains Billy Haklander. “As there was a spare bay already within the plant it was doable to make the most of this for the set up of the primary pump. The process concerned operating pumps 1, 2 and three whereas pumps 5 and 6 have been being put in. As soon as these pumps have been examined and we have been snug with their efficiency the process switched to operating pumps 4, 5 and 6 whereas pumps 1, 2, and three have been being put in.”

The introduction of the brand new pumps offered the chance to retrofit isolation valves. Traditionally the shortage of the isolation valves on the present pumps required the entire isolation of half of the discharge header board (three pumps) with a purpose to facilitate the restore to 1 pump, successfully limiting the pump capability of the plant to half of its rated capability.

The number of a mixed management/test valve to interchange two valves on every pump discharge meant that every pump would have a devoted isolation valve for every pump discharge. Isolation valves on every pump discharge will allow the entire isolation of the mix valve and the excessive raise pump for upkeep and restore functions.
A big ingredient of the venture was the energy-saving promise of the pumps, which concerned manufacturing unit acceptance testing at KSB’s Halle facility in Germany. Henderson explains: “Manufacturing facility testing concerned transport one motor of every measurement to our manufacturing unit and coupling them as much as the pumps for string testing and recording the general pump efficiency. The motors additionally underwent kind testing beneath full load in accordance with the IEEE Customary in order that they may decide motor effectivity.” He continues: “We took the manufacturing unit general energy and the info from the motor manufacturing unit to find out pump effectivity. There have been strict penalties on efficiency ensures on this venture, so if we failed to fulfill the effectivity ensures given, KSB could be required to pay LHPWSS the distinction in power prices delivered and people which have been assured over the efficiency lifetime.”

“It’s value noting that when the pump assessments have been carried out, they needed to be on naked internals. The coatings have been solely utilized after testing, so it was a real take a look at of the uncooked effectivity of the pumps. Provided that coating can enhance effectivity by one to 2 p.c we confronted some robust situations.”

“The substitute of fifty-year-old excessive raise pumps on the Lake Huron Water Remedy Plant will end in vital power financial savings and optimization of pump operations. The complexities of this huge infrastructure venture embrace the set up of two 2,000hp/1494kW and two 3,500hp/2611kW pumps and related mixture management and isolation valves in addition to a medium voltage motor management centre, all whereas sustaining provide to the utility’s regional clients,” says Billy Haklander.

“Working with KSB and the opposite distributors all through a world pandemic offered unexpected challenges, however I used to be amazed at how effectively the venture went. The individuals at KSB in Canada have been in a position to arrange and accommodate the digital website acceptance testing program and their engineers on the Halle plant in Germany have been nice in offering info when it was requested. KSB was on the entrance in making it a profitable venture and their collaboration with the important thing gamers, specifically Kenaidan Contracting the final contractor chargeable for putting in the pumps and the mechanical elements of the venture and overseeing the set up of {the electrical} elements by their electrical sub-contractor Selectra, was tremendously appreciated,” feedback Billy Haklander.

The plant has a present therapy capability of 340 million liters per day (75 million imperial gallons per day) and serves a inhabitants of roughly 420,000 individuals.